文件操作 - toc.xml
返回文件管理
返回主菜单
删除本文件
文件: /usr/local/MegaRAID Storage Manager/docs/MSM_CSA_help/wwhdata/xml/toc.xml
编辑文件内容
<?xml version="1.0" encoding="utf-8"?> <WebWorksHelpTOC version="5.0" xmlns="urn:WebWorks-Help-TOC-Schema"> <i t="Nytro MegaRAID Revision 1.7 Overview" l="1"> <i t="Nytro MegaRAID Controller Features and Benefits" l="2"> <i t="Nytro Cache Drive Group" l="3" /> <i t="Auto Configuration" l="4" /> <i t="Nytro Cache Clear" l="5" /> <i t="Monitoring the Nytro Cache Performance" l="6" /> <i t="Diagnostic Dump" l="7" /> <i t="DDR Offload" l="8" /> <i t="Monitoring and Reporting Nytro Flash Module Temperature" l="9" /> <i t="Nytro Flash Module as an External Drive" l="10" /> <i t="R1-Elastic Cache" l="11" /> <i t="Nytro Cache Drive and Boot Drive Configuration" l="12" /> <i t="Auto Physical Drive Caching" l="13" /> <i t="Force Flushing Dirty Data" l="14" /> <i t="SafeStore Disk Encryption Overview" l="15" /> <i t="LED Indicators" l="16" /> <i t="Cache Auto Assignment" l="17" /> <i t="Persistent Metadata for Read Cache" l="18" /> </i> <i t="Hardware and Software Requirements" l="19"> <i t="Operating System Support" l="20" /> <i t="Supported Devices" l="21" /> </i> <i t="SAS Technology" l="22" /> <i t="SATA II and SATA III Features" l="23" /> <i t="Configuration Scenarios" l="24" /> <i t="Solid State Drive Features" l="25"> <i t="The SSD Guard Feature" l="26" /> </i> <i t="FastPath Feature" l="27"> <i t="Controller Settings for FastPath" l="28" /> </i> <i t="Dimmer Switch Feature" l="29" /> <i t="UEFI 2.0 Support" l="30" /> <i t="MegaRAID Storage Manager Software Overview" l="31" /> <i t="References" l="32" /> <i t="Technical Support" l="33" /> </i> <i t="SafeStore Disk Encryption" l="34"> <i t="Terminology" l="35" /> <i t="Workflow" l="36"> <i t="Enable Security" l="37" /> <i t="Changing the Security Settings" l="38" /> <i t="Create Secure Virtual Drives" l="39" /> <i t="Importing a Foreign Configuration" l="40" /> </i> <i t="Instant Secure Erase" l="41" /> <i t="SafeStore Security Options" l="42"> <i t="Using Instant Secure Erase on a Physical Drive" l="43" /> <i t="Securing Data on a Virtual Drive" l="44" /> <i t="Creating a Security Key" l="45" /> <i t="Creating a Physical Drive Security Key" l="46" /> <i t="Enabling Security By Using External Key Management Server" l="47" /> <i t="Changing the Security Key" l="48" /> <i t="Securing the Virtual Drive" l="49" /> <i t="Verifying the Security Key" l="50" /> </i> </i> <i t="Nytro Flash Module Configuration" l="51"> <i t="Nytro Write Cache Policy" l="52"> <i t="Viewing the Nytro Drive Properties" l="53" /> </i> <i t="Configuring the Nytro Flash Module" l="54"> <i t="Controller Settings for Nytro Cache Drive" l="55" /> <i t="Viewing the Nytro Controller Properties" l="56" /> <i t="Specifying the Virtual Drive Parameters" l="57" /> <i t="Auto Configuration" l="58" /> <i t="Manual Configuration" l="59" /> <i t="Configuring the Nytro Flash Modules By Using the MegaRAID Storage Manager Software" l="60"> <i t="Creating Virtual Drive – Allocate Capacity" l="61" /> <i t="Creating Only Nytro Cache Drive" l="62" /> <i t="Creating a Nytro Cache Drive and Nytro Virtual Drive" l="63" /> <i t="Creating a Nytro Virtual Drive" l="64" /> <i t="Creating Spanned Drive Groups" l="65" /> </i> <i t="Deleting a Nytro Cache Drive" l="66" /> </i> <i t="Using the Nytro Cache Drive" l="67"> <i t="Associating a Source VD to a Nytro Flash Module" l="68" /> <i t="Dissociating a Source VD from Nytro Cache Drive" l="69" /> <i t="Operations Performed on the Nytro Cache Drive" l="70" /> </i> <i t="Enabling the Nytro Cache Statistics Collection" l="71" /> <i t="Recovering the Locked Nytro Flash Modules" l="72" /> </i> <i t="MegaRAID Storage Manager Window and Menus" l="73"> <i t="Starting the MegaRAID Storage Manager Software" l="74"> <i t="Discovery and Login" l="75" /> <i t="LDAP Support" l="76" /> <i t="Configuring LDAP Support Settings" l="77" /> </i> <i t="MegaRAID Storage Manager Main Menu" l="78"> <i t="GUI Elements and Menus in the MegaRAID Storage Manager Window and" l="79"> <i t="Icons" l="80" /> <i t="Properties View Tab" l="81" /> <i t="Event Log Panel" l="82" /> <i t="Menu Bar" l="83" /> </i> <i t="Dashboard View, Physical View, and Logical View" l="84" /> <i t="Creating a Storage Configuration By Using the MegaRAID Storage Manager Software" l="85"> <i t="Selecting the Virtual Drive Settings" l="86" /> <i t="Creating a Virtual Drive Using Simple Configuration" l="87" /> <i t="Creating a Virtual Drive Using Advanced Configuration" l="88" /> <i t="Changing the Virtual Drive Properties" l="89" /> <i t="Changing the Virtual Drive Configuration" l="90"> <i t="Accessing the Modify Drive Group Wizard" l="91" /> <i t="Adding Drives to a Configuration" l="92" /> <i t="Removing a Drive from a Configuration" l="93" /> <i t="Replacing a Drive" l="94" /> <i t="Migrating the RAID Level of a Virtual Drive" l="95" /> </i> <i t="New Drives Attached to a Nytro Controller" l="96" /> <i t="Creating Hotspare Drives" l="97" /> <i t="Changing Adjustable Task Rates" l="98" /> <i t="Changing Power Settings" l="99"> <i t="Enhanced Dimmer Switch Power Settings" l="100" /> <i t="Power-Save Settings–Advanced" l="101" /> <i t="Power-Save Mode" l="102" /> <i t="Power-Save Mode–SSD Drives" l="103" /> <i t="Automatically Spin-Up Drives" l="104" /> </i> <i t="Recovering and Clearing Punctured Block Entries" l="105" /> <i t="Deleting a Virtual Drive" l="106" /> </i> <i t="Physical Drive Temperature" l="107" /> <i t="Setting the Fast Path Options" l="108" /> <i t="Shield State" l="109" /> <i t="Shield State Physical View" l="110" /> <i t="Shield State Logical View" l="111" /> <i t="Viewing the Server Profile of a Drive in Shield State" l="112" /> <i t="Viewing the Physical Drive Properties" l="113" /> <i t="Viewing the Virtual Drive Properties" l="114"> <i t="Parity Size" l="115" /> <i t="Mirror Data Size" l="116" /> <i t="Metadata Size" l="117" /> </i> <i t="Emergency Spare" l="118"> <i t="Emergency Spare for Physical Drives" l="119" /> <i t="Emergency Spare Property for Controllers" l="120"> <i t="Commissioned Hotspare" l="121" /> </i> </i> <i t="Nytro Virtual Drive Policy" l="122"> <i t="Virtual Drive Settings" l="123" /> <i t="Set Virtual Drive Properties" l="124" /> </i> <i t="Non-SED Secure Erase" l="125"> <i t="Group Show Progress" l="126" /> <i t="Virtual Drive Erase" l="127" /> <i t="Group Show Progress for Virtual Drive Erase" l="128" /> </i> <i t="Rebuild Write Cache" l="129" /> <i t="Background Suspend or Resume Support" l="130" /> <i t="Enclosure Properties" l="131" /> </i> </i> <i t="Monitoring Controllers and Their Attached Devices" l="132"> <i t="Alert Delivery Methods" l="133" /> <i t="Monitoring User Events" l="134"> <i t="Vivaldi Log/MegaRAID Storage Manager Log" l="135" /> <i t="System Log" l="136" /> <i t="Pop-up Notification" l="137" /> <i t="Email Notification" l="138" /> <i t="Configuring Alert Notifications" l="139" /> <i t="Editing Alert Delivery Methods" l="140" /> <i t="Changing Alert Delivery Methods for Individual Events" l="141" /> <i t="Changing the Severity Level for Individual Events" l="142" /> <i t="Roll Back to Default Individual Event Configuration" l="143" /> <i t="Entering or Editing the Sender Email Address and SMTP Server" l="144" /> <i t="Authenticating the SMTP Server" l="145" /> <i t="Adding Email Addresses of Recipients of Alert Notifications" l="146" /> <i t="Testing Email Addresses of Recipients of Alert Notifications" l="147" /> <i t="Removing Email Addresses of Recipients of Alert Notifications" l="148" /> </i> <i t="Monitoring the Controllers" l="149"> <i t="Running a Patrol Read" l="150" /> <i t="Patrol Read Task Rates" l="151" /> </i> <i t="Monitoring Drives" l="152" /> <i t="Monitoring Virtual Drives" l="153" /> <i t="Monitoring Enclosures" l="154" /> <i t="Monitoring the SuperCap Units" l="155" /> <i t="Monitoring the SuperCap Unit" l="156"> <i t="SuperCap Learn Cycle" l="157"> <i t="Setting Automatic Learn Cycle Properties" l="158" /> <i t="Starting Learn Cycles Manually" l="159" /> </i> </i> <i t="Monitoring Rebuilds and Other Processes" l="160" /> </i> <i t="Maintaining and Managing the Storage Configurations" l="161"> <i t="Initializing a Virtual Drive" l="162"> <i t="Running a Group Initialization" l="163" /> </i> <i t="Running a Consistency Check" l="164"> <i t="Setting the Consistency Check Settings" l="165" /> <i t="Scheduling a Consistency Check" l="166" /> <i t="Running a Group Consistency Check" l="167" /> </i> <i t="Scanning for New Drives" l="168" /> <i t="Rebuilding a Drive" l="169"> <i t="New Drives Attached to a Controller" l="170" /> </i> <i t="Forcing the Offline Nytro Flash Module into Online State" l="171" /> <i t="Removing a Drive" l="172" /> <i t="Saving the Back-Up Configurations" l="173" /> <i t="Loading the Back-Up Configurations" l="174" /> <i t="Instant Secure Erase" l="175" /> <i t="Upgrading the Nytro MegaRAID Firmware and Nytro Flash Module Firmware" l="176"> <i t="Upgrading Controller Firmware By Using the MegaRAID Storage Manager Software" l="177" /> <i t="Upgrading the Nytro Controller Firmware By Using the StorCLI Utility" l="178" /> <i t="Upgrading the Nytro Flash Module Firmware By Using the StorCLI Utility" l="179" /> <i t="Verifying the Firmware Upgrade" l="180" /> </i> <i t="Migrating to Nytro Controllers" l="181" /> </i> <i t="Appendix A: Events and Messages" l="182"> <i t="Error Levels" l="183" /> <i t="Event Messages" l="184" /> </i> <i t="Appendix B: Error Messages and Descriptions" l="185"> <i t="Error Handling" l="186" /> </i> <i t="Appendix C: Other Types of Installation" l="187" /> <i t="Glossary" l="188" /> </WebWorksHelpTOC>
修改文件时间
将文件时间修改为当前时间的前一年
删除文件