文件操作 - Nytro_topic_5_3_2.html
返回文件管理
返回主菜单
删除本文件
文件: /usr/local/MegaRAID Storage Manager/docs/MSM_CSA_help/Nytro_topic_5_3_2.html
编辑文件内容
<?xml version="1.0" encoding="utf-8"?> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xml:lang="en" lang="en" xmlns="http://www.w3.org/1999/xhtml"> <head> <meta http-equiv="Content-Type" content="text/html;charset=utf-8" /> <meta http-equiv="Content-Style-Type" content="text/css" /> <!-- MOTW-DISABLED saved from url=(0014)about:internet --> <meta name="keywords" /> <title>Creating a Virtual Drive Using Simple Configuration</title> <link rel="StyleSheet" href="css/v7720452.css" type="text/css" media="all" /> <link rel="StyleSheet" href="css/webworks.css" type="text/css" media="all" /> <script type="text/javascript" language="JavaScript1.2" src="wwhdata/common/context.js"></script> <script type="text/javascript" language="JavaScript1.2" src="wwhdata/common/towwhdir.js"></script> <script type="text/javascript" language="JavaScript1.2" src="wwhdata/common/wwhpagef.js"></script> <script type="text/javascript" language="JavaScript1.2"> <!-- var WebWorksRootPath = ""; // --> </script> <script type="text/javascript" language="JavaScript1.2"> <!-- // Set reference to top level help frame // var WWHFrame = WWHGetWWHFrame("", true); // --> </script> <script type="text/javascript" language="JavaScript1.2" src="scripts/expand.js"></script> </head> <body onload="WWHUpdate();" onunload="WWHUnload();" onkeydown="WWHHandleKeyDown((document.all||document.getElementById||document.layers)?event:null);" onkeypress="WWHHandleKeyPress((document.all||document.getElementById||document.layers)?event:null);" onkeyup="WWHHandleKeyUp((document.all||document.getElementById||document.layers)?event:null);"> <br /> <div class="WebWorks_Breadcrumbs" style="text-align: left;"> <a class="WebWorks_Breadcrumb_Link" href="Nytro_topic_4.html#3_10_8_10_8_1">MegaRAID Storage Manager Window and Menus</a> : <a class="WebWorks_Breadcrumb_Link" href="Nytro_topic_5.html#3_10_8_10_8_1">MegaRAID Storage Manager Main Menu</a> : <a class="WebWorks_Breadcrumb_Link" href="Nytro_topic_5_3.html#3_10_8_10_8_1">Creating a Storage Configuration By Using the MegaRAID Storage Manager Software</a> : Creating a Virtual Drive Using Simple Configuration</div> <hr align="left" /> <blockquote> <p class="Heading_3"><a name="3_10_8_10_8_1">Creating a Virtual Drive Using Simple Configuration</a></p> <p class="Body"><a name="3_10_8_10_8_3_1_2">Simple configuration is the quickest and easiest way to create a new storage configuration. When you select simple configuration mode, the system creates the best configuration possible using the available drives.</a></p> <p class="note"> <span style="font-family: Sans-Serif; font-weight: bold">NOTE </span><a name="3_10_8_10_8_3_1_3">You cannot create spanned drives using the simple configuration procedure. To create spanned drives, use the advanced configuration procedure described in </a><span class="fm_003aParaText"><a href="javascript:WWHClickedPopup('NMR_v1.7', 'Nytro_topic_5_3_3.html#3_10_8_10_10_1', '');" title="Creating a Virtual Drive Using Advanced Configuration">Creating a Virtual Drive Using Advanced Configuration</a></span>.</p> <p class="Body"><a name="3_10_8_10_8_3_1_4">Follow these steps to create a new storage configuration in simple configuration mode.</a></p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">1. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_1">Perform either of the following steps:</a></span></p> </td> </tr> </table> </div> <div class="List_2_outer" style="margin-left: 26px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="List_2_inner" style="width: 18pt; white-space: nowrap"> <img src="line.png" alt="*" border="0" width="5" height="5" /> </p> </td> <td width="100%"> <p class="List_2_inner"><a name="3_10_8_10_8_3_2_1_4_1">Right-click the controller node in the device tree in the left frame of the </a><span class="wintitle">MegaRAID Storage Manager</span> window, and select <span class="uicontrol">Create Virtual Drive</span>.</p> </td> </tr> </table> </div> <div class="List_2_outer" style="margin-left: 26px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="List_2_inner" style="width: 18pt; white-space: nowrap"> <img src="line.png" alt="*" border="0" width="5" height="5" /> </p> </td> <td width="100%"> <p class="List_2_inner"><a name="3_10_8_10_8_3_2_1_4_2">Select the controller node, and select </a><span class="uicontrol">Go To > Controller > Create Virtual Drive</span> in the menu bar.</p> </td> </tr> </table> </div> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">2. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_2">Select the </a></span><span class="uicontrol">Simple</span><span class="Command"> radio button, and click </span><span class="uicontrol">Next</span><span class="Command">.</span></p> </td> </tr> </table> </div> <p class="Body_1"><a name="3_10_8_10_8_3_2_2_4_2">The </a><span class="wintitle">Create Virtual Drive-Allocate capacity</span> dialog appears, as shown in the following figure. If unconfigured drives are available, you have the option to use those unconfigured drives. If unconfigured drives are available, the <span class="wintitle">Create Drive Group Settings</span> dialog appears, and you can go to step <span class="fm_003aNumberOnly">#v6354791/CEGGHEDJ</span>.</p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">3. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_3">Perform either of the two options:</a></span></p> </td> </tr> </table> </div> <div class="List_2_outer" style="margin-left: 26px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="List_2_inner" style="width: 18pt; white-space: nowrap"> <img src="line.png" alt="*" border="0" width="5" height="5" /> </p> </td> <td width="100%"> <p class="List_2_inner"><a name="3_10_8_10_8_3_2_3_4_1">If a drive group exists, select the </a><span class="uicontrol">Use free capacity on an existing drive group</span> radio button and click <span class="uicontrol">Next</span>. Continue with step <span class="fm_003aNumberOnly">#v6354791/CEGGHEDJ</span>. The <span class="wintitle">Create Virtual Drive</span> dialog appears, as shown in the following figure. If different types of drives are attached to the controller, such as HDD, SDD, SAS, and SATA, an option appears to allow drive type mixing.</p> </td> </tr> </table> </div> <div class="List_2_outer" style="margin-left: 26px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="List_2_inner" style="width: 18pt; white-space: nowrap"> <img src="line.png" alt="*" border="0" width="5" height="5" /> </p> </td> <td width="100%"> <p class="List_2_inner"><a name="3_10_8_10_8_3_2_3_4_2">If unconfigured drives are available, select the radio button to use the unconfigured drives, and click </a><span class="uicontrol">Next</span>. Continue with step <span class="fm_003aNumberOnly">#v6354791/CEGBHAHJ</span>. The Summary window appears as shown in <span class="fm_003aParaTypeWithNumber">#v6354791/CEGBDAAC</span>.</p> </td> </tr> </table> </div> <p class="Figure_Title">Figure 40. <a name="3_10_8_10_8_3_2_3_5_2_2">Create Virtual Drive–Drive group and Virtual drive settings Dialog</a></p> <p class="Figure_1"><a name="3_10_8_10_8_3_2_3_5_2-2"><img class="Default" src="images/Figure_29_Nytro_MSM_27_Simple_config_DG_VG_settings.png" width="503" height="396" style="display: block; float: none; left: 0pt; top: 0pt" alt="" /></a></p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">4. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_4">If you want to allow different types of drives in a configuration, select the </a></span><span class="uicontrol">Use the drive type mixing</span><span class="Command"> check box.</span></p> </td> </tr> </table> </div> <p class="note_1"> <span style="font-family: Sans-Serif; font-weight: bold">NOTE </span><a name="3_10_8_10_8_3_2_4_4_2">For best results, do not use drive type mixing.</a></p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">5. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_5">Select the RAID level desired for the virtual drive.</a></span></p> </td> </tr> </table> </div> <p class="Body_1"><a name="3_10_8_10_8_3_2_5_4_2">When you use simple configuration, the RAID controller supports RAID 1 and RAID 5. In addition, it supports independent drives (configured as RAID 0). The window text gives a brief description of the RAID level that you select. The RAID levels that you can choose depend on the number of drives available.</a></p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">6. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_6">Select the </a></span><span class="uicontrol">Assign a hot spare</span><span class="Command"> check box if you want to assign a dedicated hotspare to the new virtual drive.</span></p> </td> </tr> </table> </div> <p class="Body_1"><a name="3_10_8_10_8_3_2_6_4_2">If an unconfigured good drive is available, that drive is assigned as a hot pare. Hotspares are drives that are available to replace failed drives automatically in a redundant virtual drive (RAID 1 and RAID 5).</a></p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">7. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_7">Select the </a></span><span class="uicontrol">Use drive security</span><span class="Command"> check box if you want to set a drive security method.</span></p> </td> </tr> </table> </div> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">8. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_8">Use the drop-down list in the </a></span><span class="uicontrol">Virtual drives</span><span class="Command"> field to choose how many virtual drives you want to create.</span></p> </td> </tr> </table> </div> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">9. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_9">Select the capacity of the virtual drives.</a></span></p> </td> </tr> </table> </div> <p class="Body_1"><a name="3_10_8_10_8_3_2_9_4_2">Each virtual drive has the same capacity.</a></p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">10. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_10">Click </a></span><span class="uicontrol">Next</span><span class="Command">.</span></p> </td> </tr> </table> </div> <p class="Body_1"><a name="3_10_8_10_8_3_2_10_4_2">The </a><span class="wintitle">Create Virtual Drive - Summary</span> dialog appears. This window shows the selections you made for simple configuration.</p> <div class="Step_1_outer" style="margin-left: 1px"> <table border="0" cellspacing="0" cellpadding="0" summary="" role="presentation"> <tr style="vertical-align: baseline"> <td> <p class="Step_1_inner" style="width: 18pt; white-space: nowrap">11. </p> </td> <td width="100%"> <p class="Step_1_inner"><span class="Command"><a name="3_10_8_10_8_3_2_11">Either click </a></span><span class="uicontrol">Back</span><span class="Command"> to return to the previous dialog to change any selections, or click </span><span class="uicontrol">Finish</span><span class="Command"> to accept and complete the configuration.</span></p> </td> </tr> </table> </div> <p class="Body_1"><a name="3_10_8_10_8_3_2_11_4_2">The new virtual drive is created after you click </a><span class="uicontrol">Finish</span>. After the configuration is completed, a dialog box notifies you that the virtual drives were created successfully.</p> <p class="note_1"> <span style="font-family: Sans-Serif; font-weight: bold">NOTE </span><a name="3_10_8_10_8_3_2_11_4_3">If you create a large configuration using drives that are in Power-save mode, it could take several minutes to spin up the drives. A progress bar appears as the drives spin up. If any of the selected unconfigured drives fail to spin up, a dialog box that identifies these drives appears.</a></p> <script type="text/javascript" language="JavaScript1.2"> <!-- // Clear related topics // WWHClearRelatedTopics(); document.writeln(WWHRelatedTopicsInlineHTML()); // --> </script> </blockquote> <hr align="left" /> <!-- LSI changed location of company info to align left --> <!-- Added rol from 2011.3 pages.asp file --> <!-- LSI added copyright style --> <!-- --> <table align="left" role="presentation"> <!-- LSI added support for booknum and reldate --> <!-- --> <tr> <td class="copyright">DB15-000988-08-December 2013</td> </tr> <tr> <td class="copyright"> <a href="http://www.lsi.com/Pages/trademark.aspx?" target="external_window">Copyright© 2013 by LSI Corporation. All rights reserved.</a> </td> </tr> </table> <script type="text/javascript" language="JavaScript1.2"> <!-- document.write(WWHRelatedTopicsDivTag() + WWHPopupDivTag() + WWHALinksDivTag()); // --> </script> </body> </html>
修改文件时间
将文件时间修改为当前时间的前一年
删除文件