文件操作 - MR_Events.properties
返回文件管理
返回主菜单
删除本文件
文件: /usr/local/MegaRAID Storage Manager/Languages/en/MR_Events.properties
编辑文件内容
############################################################################## #This property file contains the English language strings for all MSM events # # # MR_EVENTS_DETAILS(PROPERTIES FILE) # # # ############################################################################## 0 = Controller ID: {0} Firmware initialization started: (PCI ID {1}/{2}/{3}/{4}) 1 = Controller ID: {0} Image version {1} 2 = Controller ID: {0} Unable to recover cache data from TBBU 3 = Controller ID: {0} Cache data recovered from TBBU successfully 4 = Controller ID: {0} Configuration cleared 5 = Controller ID: {0} Cluster down; communication with peer lost 6 = Controller ID: {0} Logical drive ownership changed: VD = {1} Previous = {2} Current = {3} 7 = Controller ID: {0} Alarm disabled by user 8 = Controller ID: {0} Alarm enabled by user 9 = Controller ID: {0} Background initialization rate changed: {1}% 10 = Controller ID: {0} Controller cache discarded due to memory/battery problems 11 = Controller ID: {0} Unable to recover cache data due to configuration mismatch 12 = Controller ID: {0} Cache data recovered successfully 13 = Controller ID: {0} Controller cache discarded due to firmware version incompatibility 14 = Controller ID: {0} Consistency Check rate changed: {1}% 15 = Controller ID: {0} Fatal firmware error: {1} 16 = Controller ID: {0} Factory defaults restored 17 = Controller ID: {0} Flash downloaded image corrupt 18 = Controller ID: {0} Flash erase error 19 = Controller ID: {0} Flash timeout during erase 20 = Controller ID: {0} Flash error 21 = Controller ID: {0} Flashing image: {1} 22 = Controller ID: {0} Flash of new firmware image(s) complete 23 = Controller ID: {0} Flash programming error 24 = Controller ID: {0} Flash timeout during programming 25 = Controller ID: {0} Flash chip type unknown 26 = Controller ID: {0} Flash command set unknown 27 = Controller ID: {0} Flash verify failure 28 = Controller ID: {0} Flush rate changed: {1} Seconds 29 = Controller ID: {0} Hibernate command received from host 30 = Controller ID: {0} Event log cleared 31 = Controller ID: {0} Event log wrapped 32 = Controller ID: {0} Multi-bit ECC error:ECAR = {1} , ELOG = {2} ,({3}) 33 = Controller ID: {0} Single-bit ECC error:ECAR = {1} , ELOG = {2} ,({3}) 34 = Controller ID: {0} Not enough controller memory 35 = Controller ID: {0} Patrol Read complete 36 = Controller ID: {0} Patrol Read paused 37 = Controller ID: {0} Patrol Read Rate changed: {1}% 38 = Controller ID: {0} Patrol Read resumed 39 = Controller ID: {0} Patrol Read started 40 = Controller ID: {0} Rebuild rate changed: {1}% 41 = Controller ID: {0} Reconstruction rate changed: {1}% 42 = Controller ID: {0} Shutdown command received from host 43 = Controller ID: {0} Test event: '{1}' 44 = Controller ID: {0} Time established since power on: TIME {1} {2} Seconds 45 = Controller ID: {0} User entered firmware debugger 46 = Controller ID: {0} Background Initialization aborted on VD: {1} 47 = Controller ID: {0} Background Initialization corrected medium error: (VD {1} Location {2}, PD {3} Location {4}) 48 = Controller ID: {0} Background Initialization completed on VD: {1} 49 = Controller ID: {0} Background Initialization completed with uncorrectable errors on VD: {1} 50 = Controller ID: {0} Background Initialization detected uncorrectable multiple medium errors: (PD {1} Location {2}, VD {3}) 51 = Controller ID: {0} Background Initialization failed on VD: {1} 52 = Controller ID: {0} Background Initialization progress: {1}% 53 = Controller ID: {0} Background Initialization started on VD:{1} 54 = Controller ID: {0} Policy change on VD: {1} Previous = {2} Now = {3} 55 = Controller ID: {0} OBSOLETE 56 = Controller ID: {0} Consistency Check aborted on VD: {1} 57 = Controller ID: {0} Consistency Check corrected medium error:(VD {1} Location {2}, PD {3} Location {4}) 58 = Controller ID: {0} Consistency Check done on VD: {1} 59 = Controller ID: {0} Consistency Check done with corrections on VD: {1}, (corrections = {2}) 60 = Controller ID: {0} Consistency Check detected uncorrectable multiple medium errors: (PD {1} Location {2}, VD {3}) 61 = Controller ID: {0} Consistency Check failed on VD: {1} 62 = Controller ID: {0} Consistency Check completed with uncorrectable errors on VD: {1} 63 = Controller ID: {0} Consistency Check found inconsistent parity on VD strip: (VD = {1}, strip = {2}) 64 = Controller ID: {0} Consistency Check inconsistency logging disabled, too many inconsistencies on VD: {1} 65 = Controller ID: {0} Consistency Check progress: VD = {1} 66 = Controller ID: {0} Consistency Check started on VD: {1} 67 = Controller ID: {0} Initialization aborted on VD: {1} 68 = Controller ID: {0} Initialization failed on VD: {1} 69 = Controller ID: {0} Initialization progress on VD: {1} Progress = {2}% 70 = Controller ID: {0} Fast initialization started on VD: {1} 71 = Controller ID: {0} Full initialization started on VD: {1} 72 = Controller ID: {0} Initialization complete on VD: {1} 73 = Controller ID: {0} Properties updated on VD: {1} Previous = {2} Now = {3} 74 = Controller ID: {0} Reconstruction complete: VD {1} 75 = Controller ID: {0} Reconstruction stopped due to unrecoverable errors: VD {1} 76 = Controller ID: {0} Reconstruct detected uncorrectable multiple medium errors: (VD {1} Location {2}, PD {3} Location {4}) 77 = Controller ID: {0} Reconstruction progress: VD {1} Progress {2}% 78 = Controller ID: {0} Reconstruction resumed: VD {1} 79 = Controller ID: {0} Reconstruction resume failed due to configuration mismatch: VD {1} 80 = Controller ID: {0} Reconstruction started: VD {1} 81 = Controller ID: {0} State change on VD: {1} Previous = {2} Current = {3} 82 = Controller ID: {0} PD Clear aborted: {1} 83 = Controller ID: {0} PD Clear failed: {1} (Error {2}) 84 = Controller ID: {0} PD Clear progress: {1} Progress = {2}% 85 = Controller ID: {0} PD Clear started: {1} 86 = Controller ID: {0} PD Clear completed: {1} 87 = Controller ID: {0} Error: {1} (Error {2}) 88 = Controller ID: {0} Format complete: {1} 89 = Controller ID: {0} Format started: {1} 90 = Controller ID: {0} Hot Spare SMART polling failed: {1} (Error {2}) 91 = Controller ID: {0} PD inserted: {1} 92 = Controller ID: {0} PD is not supported: {1} 93 = Controller ID: {0} Patrol Read corrected medium error: PD {1} Location {2} 94 = Controller ID: {0} Patrol Read progress: PD {1} Progress {2}% 95 = Controller ID: {0} Patrol Read found an uncorrectable medium error: PD {1} Location {2} 96 = Controller ID: {0} PD Predictive failure: {1} 97 = Controller ID: {0} Puncturing bad block: PD {1} Location {2} 98 = Controller ID: {0} Rebuild aborted by user: PD {1} 99 = Controller ID: {0} Rebuild complete on VD {1} 100 = Controller ID: {0} Rebuild complete {1} 101 = Controller ID: {0} Rebuild failed due to source drive error: PD {1} 102 = Controller ID: {0} Rebuild failed due to target drive error: PD {1} 103 = Controller ID: {0} Rebuild progress: PD {1} Progress {2} 104 = Controller ID: {0} Rebuild resumed: PD {1} 105 = Controller ID: {0} Rebuild started: PD {1} 106 = Controller ID: {0} Rebuild automatically started: PD {1} 107 = Controller ID: {0} Rebuild stopped due to loss of cluster ownership: PD {1} 108 = Controller ID: {0} Reassign write operation failed: PD {1} Location {2} 109 = Controller ID: {0} Unrecoverable medium error during rebuild: PD {1} Location {2} 110 = Controller ID: {0} Corrected medium error during recovery: PD {1} Location {2} 111 = Controller ID: {0} Unrecoverable medium error during recovery: PD {1} Location {2} 112 = Controller ID: {0} PD removed: {1} 113 = Controller ID: {0} Unexpected sense: PD = {1}, CDB = {2}, Sense = {3} 114 = Controller ID: {0} State change: PD = {1} Previous = {2} Current = {3} 115 = Controller ID: {0} State change by user: PD = {1} Previous = {2} Current = {3} 116 = Controller ID: {0} Redundant path broken: {1} 117 = Controller ID: {0} Redundant path restored: {1} 118 = Controller ID: {0} Dedicated Hot Spare no longer useful due to deleted array: PD = {1} 119 = Controller ID: {0} SAS topology error: Loop detected 120 = Controller ID: {0} SAS topology error: Device not addressable 121 = Controller ID: {0} SAS topology error: Multiple ports to the same SAS address 122 = Controller ID: {0} SAS topology error: Expander error 123 = Controller ID: {0} SAS topology error: SMP timeout 124 = Controller ID: {0} SAS topology error: Out of route entries 125 = Controller ID: {0} SAS topology error: Index not found 126 = Controller ID: {0} SAS topology error: SMP function failed 127 = Controller ID: {0} SAS topology error: SMP CRC error 128 = Controller ID: {0} SAS topology error: Multiple subtractive 129 = Controller ID: {0} SAS topology error: Table to table 130 = Controller ID: {0} SAS topology error: Multiple paths 131 = Controller ID: {0} Unable to access device PD {1} 132 = Controller ID: {0} Dedicated Hot Spare created: PD {1} 133 = Controller ID: {0} Dedicated Hot Spare disabled: PD {1} 134 = Controller ID: {0} Dedicated Hot Spare no longer useful for all arrays: {1} 135 = Controller ID: {0} Global Hot Spare created: {1} 136 = Controller ID: {0} Global Hot Spare disabled: {1} 137 = Controller ID: {0} Global Hot Spare does not cover all arrays {1} 138 = Controller ID: {0} Created VD: {1} 139 = Controller ID: {0} Deleted VD: {1} 140 = Controller ID: {0} VD Marked inconsistent due to active writes at shutdown: VD {1} 141 = Controller ID: {0} Battery Present 142 = Controller ID: {0} Battery Not Present 143 = Controller ID: {0} New Battery Detected 144 = Controller ID: {0} Battery has been replaced 145 = Controller ID: {0} Battery temperature is high 146 = Controller ID: {0} Battery voltage low 147 = Controller ID: {0} Battery started charging 148 = Controller ID: {0} Battery is discharging 149 = Controller ID: {0} Battery temperature is normal 150 = Controller ID: {0} Battery has failed and cannot support data retention. Please replace the battery 151 = Controller ID: {0} Battery relearn started 152 = Controller ID: {0} Battery relearn in progress 153 = Controller ID: {0} Battery relearn completed 154 = Controller ID: {0} Battery relearn timed out 155 = Controller ID: {0} Battery relearn pending: Battery is under charge 156 = Controller ID: {0} Battery relearn postponed 157 = Controller ID: {0} Battery relearn will start in 4 days 158 = Controller ID: {0} Battery relearn will start in 2 days 159 = Controller ID: {0} Battery relearn will start in 1 day 160 = Controller ID: {0} Battery relearn will start in 5 hours 161 = Controller ID: {0} Battery removed 162 = Controller ID: {0} Current capacity of the battery is below threshold 163 = Controller ID: {0} Current capacity of the battery is above threshold 164 = Controller ID: {0} SES enclosure discovered: {1} 165 = Controller ID: {0} SAF-TE enclosure discovered: {1} 166 = Controller ID: {0} Communication lost on enclosure: {1} 167 = Controller ID: {0} Communication restored on enclosure: {1} 168 = Controller ID: {0} Fan failed on enclosure: {1} Fan {2} 169 = Controller ID: {0} Fan inserted on enclosure: {1} Fan {2} 170 = Controller ID: {0} Fan removed on enclosure: {1} Fan {2} 171 = Controller ID: {0} Power supply failed on enclosure: {1} Power Supply {2} 172 = Controller ID: {0} Power supply inserted on enclosure: {1} Power Supply {2} 173 = Controller ID: {0} Power supply removed on enclosure: {1} Power Supply {2} 174 = Controller ID: {0} ESM failed on enclosure: {1} ESM {2} 175 = Controller ID: {0} ESM inserted on enclosure: {1} ESM {2} 176 = Controller ID: {0} SIM removed on enclosure: {1} ESM {2} 177 = Controller ID: {0} Temperature sensor below warning threshold on enclosure: {1} Sensor {2} 178 = Controller ID: {0} Temperature sensor below error threshold on enclosure: {1} Sensor {2} 179 = Controller ID: {0} Temperature sensor above warning threshold on enclosure: {1} Sensor {2} 180 = Controller ID: {0} Temperature sensor above error threshold on enclosure: {1} Sensor {2} 181 = Controller ID: {0} Enclosure shutdown: {1} 182 = Controller ID: {0} Too many enclosures connected to port. Enclosure not supported: {1} 183 = Controller ID: {0} Firmware mismatch on enclosure: {1} 184 = Controller ID: {0} Sensor bad on enclosure: {1} Sensor {2} 185 = Controller ID: {0} Phy is bad on enclosure: {1} PHY {2} 186 = Controller ID: {0} Unstable Enclosure: {1} 187 = Controller ID: {0} Hardware error on enclosure: {1} 188 = Controller ID: {0} No response from enclosure: {1} 189 = Controller ID: {0} SAS/SATA mixing not supported in enclosure; disabled PD: {1} 190 = Controller ID: {0} Unsupported hotplug was detected on SES enclosure: {1} 191 = Controller ID: {0} Clustering enabled 192 = Controller ID: {0} Clustering disabled 193 = Controller ID: {0} PD too small to be used for auto-rebuild: {1} 194 = Controller ID: {0} BBU enabled; changing WT logical drives to WB 195 = Controller ID: {0} BBU disabled; changing WB logical drives to WT, Forced WB VDs are not affected 196 = Controller ID: {0} Bad block table is 80% full on PD: {1} 197 = Controller ID: {0} Bad block table is full; unable to log block: PD = {1}, Block = {2} 198 = Controller ID: {0} Consistency Check Aborted Due to Ownership Loss on VD: {1} 199 = Controller ID: {0} Background Initialization (BGI) aborted due to ownership loss on VD: {1} 200 = Controller ID: {0} Battery/charger problems detected; SOH Bad 201 = Controller ID: {0} Single-bit ECC error; warning threshold exceeded: ECAR = {1} ELOG = {2} ({3}) 202 = Controller ID: {0} Single-bit ECC error; critical threshold exceeded: ECAR = {1} ELOG = {2} ({3}) 203 = Controller ID: {0} Single-bit ECC error; further reporting disabled: ECAR = {1} ELOG = {2} ({3}) 204 = Controller ID: {0} Power supply switched off for enclosure: {1} Power Supply {2} 205 = Controller ID: {0} Power supply switched on for enclosure: {1} Power Supply {2} 206 = Controller ID: {0} Power supply cable removed on enclosure: {1} Power Supply {2} 207 = Controller ID: {0} Power supply cable inserted on enclosure: {1} Power Supply {2} 208 = Controller ID: {0} Fan returned to normal on enclosure: {1} Fan {2} 209 = Controller ID: {0} BBU Retention test was initiated on previous boot 210 = Controller ID: {0} BBU Retention test passed 211 = Controller ID: {0} BBU Retention test failed! 212 = Controller ID: {0} NVRAM Retention test was initiated on previous boot 213 = Controller ID: {0} NVRAM Retention test passed 214 = Controller ID: {0} NVRAM Retention test failed! 215 = Controller ID: {0} Successfully completed test: {1} passes = {2} 216 = Controller ID: {0} FAILED Test: {1} Pass = {2} Fail Data:ErrorOffset = {3} GoodData = {4} BadData = {5} 217 = Controller ID: {0} Self check diagnostics completed 218 = Controller ID: {0} Foreign Configuration Detected 219 = Controller ID: {0} Foreign Configuration Imported 220 = Controller ID: {0} Foreign Configuration Cleared 221 = Controller ID: {0} NVRAM is corrupt; reinitializing 222 = Controller ID: {0} NVRAM mismatch occurred 223 = Controller ID: {0} Link lost on SAS wide port: {1} PHY = {2} 224 = Controller ID: {0} Link restored on SAS wide port: {1} PHY = {2} 225 = Controller ID: {0} Allowed error rate exceeded on SAS port: {1} PHY = {2} 226 = Controller ID: {0} Bad block reassigned: {1} Previous = {2} Current = {3} 227 = Controller ID: {0} Controller Hot Plug detected 228 = Controller ID: {0} Temperature sensor differential detected on enclosure: {1} Sensor {2} 229 = Controller ID: {0} Disk test cannot start. No qualifying disks found 230 = Controller ID: {0} Time duration provided by host is not sufficient for self check 231 = Controller ID: {0} Marked Missing on array: {1} Array {2} Row {3} 232 = Controller ID: {0} Replaced Missing on array: {1} Array {2} Row {3} 233 = Controller ID: {0} Temperature returned to normal on enclosure: {1} Space {2} 234 = Controller ID: {0} Firmware download in progress on enclosure: {1} 235 = Controller ID: {0} Firmware download failed on enclosure: {1} 236 = Controller ID: {0} Drive is not certified: {1} 237 = Controller ID: {0} Dirty Cache data discarded by user 238 = Controller ID: {0} PDs missing from configuration at boot 239 = Controller ID: {0} VDs missing drives and will go offline at boot {1} 240 = Controller ID: {0} VDs missing at boot {1} 241 = Controller ID: {0} Previous configuration completely missing at boot 242 = Controller ID: {0} Battery charge complete 243 = Controller ID: {0} Fan speed changed on enclosure: {1} Fan {2} 244 = Controller ID: {0} Dedicated spare imported as global due to missing arrays PD {1} 245 = Controller ID: {0} PD rebuild not possible as SAS/SATA is not supported in an array PD {1} 246 = Controller ID: {0} SEP has been rebooted as a part of enclosure firmware download. SEP will be unavailable until reboot completes. SEP {1} 247 = Controller ID: {0} Device inserted Device Type: {1} Device Id: {2} 248 = Controller ID: {0} Device removed Device Type: {1} Device Id: {2} 249 = Controller ID: {0} VD is now OPTIMAL VD {1} 250 = Controller ID: {0} VD is now PARTIALLY DEGRADED VD {1} 251 = Controller ID: {0} VD is now DEGRADED VD {1} 252 = Controller ID: {0} VD is now OFFLINE VD {1} 253 = Controller ID: {0} Battery requires reconditioning; please initiate a LEARN cycle 254 = Controller ID: {0} VD disabled because RAID-5 is not supported by this RAID key VD {1} 255 = Controller ID: {0} VD disabled because RAID-6 is not supported by this controller VD {1} 256 = Controller ID: {0} VD disabled because SAS drives are not supported by this RAID key VD {1} 257 = Controller ID: {0} PD missing VD {1} 258 = Controller ID: {0} Puncturing of LBAs enabled 259 = Controller ID: {0} Puncturing of LBAs disabled 260 = Controller ID: {0} Enclosure ESM not installed {1} ESM {2} 261 = Controller ID: {0} Package version {1} 262 = Controller ID: {0} Global affinity Hot Spare commissioned in a different enclosure {1} 263 = Controller ID: {0} Foreign configuration table overflow 264 = Controller ID: {0} Partial foreign configuration imported, PDs not imported: {1} 265 = Controller ID: {0} Connector is active: {1} 266 = Controller ID: {0} Board Revision: {1} 267 = Controller ID: {0} Command timeout on PD: PD = {1}, CDB = {2}, Sense = {3}, Path = {4} 268 = Controller ID: {0} PD Reset: PD = {1}, Error = {2}, Path = {3} 269 = Controller ID: {0} VD bad block table is 80% full: VD {1} 270 = Controller ID: {0} VD bad block table is full - unable to log block: VD {1} 271 = Controller ID: {0} Uncorrectable medium error logged: (VD {1} Location {2}, PD {3} Location {4}) 272 = Controller ID: {0} VD medium error corrected: VD {1} Location {2} 273 = Controller ID: {0} PD Bad block table is 100% full: PD {1} 274 = Controller ID: {0} VD Bad block table is 100% full: VD {1} 275 = Controller ID: {0} Controller needs replacement since IOP is faulty 276 = Controller ID: {0} Replace drive operation started on PD: {1} Source PD: {2} 277 = Controller ID: {0} Replace drive operation aborted on PD: {1} Source PD: {2} 278 = Controller ID: {0} Replace drive operation completed on PD: {1} Source PD: {2} 279 = Controller ID: {0} Replace drive operation progress on PD: {1} Progress {2}% 280 = Controller ID: {0} Replace drive operation resumed on PD: {1} Source PD: {2} 281 = Controller ID: {0} Replace drive operation automatically started on PD: {1} Source PD: {2} 282 = Controller ID: {0} Replace drive operation failed due to source drive error on PD: {1} Source PD: {2} 283 = Controller ID: {0} Early power off warning was unsuccessful 284 = Controller ID: {0} BBU FRU is: {1} 285 = Controller ID: {0} PD FRU is: PD: {1} FRU: {1} 286 = Controller ID: {0} Controller hardware revision id is: {1} 287 = Controller ID: {0} Foreign import shall result in a backward incompatible upgrade of configuration metadata 288 = Controller ID: {0} Redundant path restored PD: {1} Path: {2} SAS Address: {3} 289 = Controller ID: {0} Redundant path broken PD: {1} Path: {2} SAS Address: {3} 290 = Controller ID: {0} Redundant enclosure module inserted Redundant: {1} Primary: {2} 291 = Controller ID: {0} Redundant enclosure module removed Redundant: {1} Primary: {2} 292 = Controller ID: {0} Patrol Read can't be started, as PDs are either not ONLINE, or are in a VD with an active process, or are in an excluded VD 293 = Controller ID: {0} Replace drive operation aborted by user on PD: {1} Source PD: {2} 294 = Controller ID: {0} Replace drive operation aborted on the hot spare as hot spare needed for rebuild. Hot Spare PD: {1} Source PD: {2} 295 = Controller ID: {0} Replace drive operation aborted as rebuild required in the array. PD: {1} Source PD: {2} 296 = Controller ID: {0} Controller cache discarded for missing or offline VD VD {1} 297 = Controller ID: {0} Replace drive operation cannot be started as drive is too small. PD: {1} Source PD: {2} 298 = Controller ID: {0} Replace drive operation cannot be started as SAS/SATA is not supported in an array. PD: {1} Source PD: {2} 299 = Controller ID: {0} Microcode update started on PD: {1} 300 = Controller ID: {0} Microcode update completed on PD: {1} 301 = Controller ID: {0} Microcode update timeout on PD: {1} 302 = Controller ID: {0} Microcode update failed on PD: {1} 303 = Controller ID: {0} Controller properties changed 304 = Controller ID: {0} Patrol Read properties changed 305 = Controller ID: {0} CC Schedule properties changed 306 = Controller ID: {0} Battery properties changed 307 = Controller ID: {0} Periodic Battery Relearn is pending. Please initiate manual learn cycle as Automatic learn is not enabled 308 = Controller ID: {0} Drive security key created 309 = Controller ID: {0} Drive security key backed up 310 = Controller ID: {0} Drive security key from escrow, verified 311 = Controller ID: {0} Drive security key changed 312 = Controller ID: {0} Drive security key, re-key operation failed 313 = Controller ID: {0} Drive security key is invalid 314 = Controller ID: {0} Drive security key destroyed 315 = Controller ID: {0} Drive security key from escrow is invalid 316 = Controller ID: {0} VD is now secured: VD {1} 317 = Controller ID: {0} VD is partially secured: VD {1} 318 = Controller ID: {0} PD security activated: PD {1} 319 = Controller ID: {0} PD security disabled: PD {1} 320 = Controller ID: {0} PD is reprovisioned: PD {1} 321 = Controller ID: {0} PD security key changed: PD {1} 322 = Controller ID: {0} Security subsystem problems detected for PD: PD {1} 323 = Controller ID: {0} Controller cache pinned for missing or offline VD: VD {1} 324 = Controller ID: {0} Controller cache pinned for missing or offline VDs: VD {1} 325 = Controller ID: {0} Controller cache discarded by user for missing VDs: VD {1} 326 = Controller ID: {0} Controller cache destaged for VD: VD {1} 327 = Controller ID: {0} Consistency Check started on an inconsistent VD: VD {1} 328 = Controller ID: {0} Drive security key failure, cannot access secured configuration 329 = Controller ID: {0} Drive security pass phrase from user is invalid 330 = Controller ID: {0} Detected error with the remote battery connector cable 331 = Controller ID: {0} Power state change on PD = {1} Previous = {2} Current = {3} 332 = Controller ID: {0} Enclosure element status changed Enclosure {1} SES code {2} 333 = Controller ID: {0} Rebuild is not allowed on PD as HDD/SSD mix is not supported in VDs. PD: {1} 334 = Controller ID: {0} Replace drive operation is not allowed on PD as HDD/SSD mix is not supported in VDs. PD: {1} Source PD: {2} 335 = Controller ID: {0} VD Bad block table is cleared. VD: {1} 336 = Controller ID: {0} SAS topology error: {1} 337 = Controller ID: {0} VD cluster of medium errors corrected: (VD {1} Location {2}, PD {3} Location {4}) 338 = Controller ID: {0} Controller requests a host bus rescan 339 = Controller ID: {0} Controller repurposed and factory defaults restored 340 = Controller ID: {0} Drive security key binding updated 341 = Controller ID: {0} Drive security is in EKM mode 342 = Controller ID: {0} Drive security failed to communicate with EKMS 343 = Controller ID: {0} PD needs key to be {1} PD: {2} KeyId Length: {3} 344 = Controller ID: {0} VD secure failed: {1} 345 = Controller ID: {0} Controller encountered a fatal error and was reset 346 = Controller ID: {0} Snapshot enabled on VD {1} SnapShot Repository VD: {2} 347 = Controller ID: {0} Snapshot disabled by the user on VD {1} SnapShot Repository VD: {2} 348 = Controller ID: {0} Snapshot disabled on VD {1} SnapShot Repository VD: {2} 349 = Controller ID: {0} Snapshot Point In Time created on VD {1} PIT creation time {2} 350 = Controller ID: {0} Snapshot Point In Time deleted on VD {1} PIT creation time {2} 351 = Controller ID: {0} Snapshot View created on VD {1} PIT creation time {2} Snapshot view creation time {3} 352 = Controller ID: {0} Snapshot View deleted on VD {1} PIT creation time {2} Snapshot view creation time {3} 353 = Controller ID: {0} Snapshot rollback started for Point In Time on VD {1} PIT creation time {2} 354 = Controller ID: {0} Snapshot rollback internally aborted for Point In Time on VD {1} PIT creation time {2} 355 = Controller ID: {0} Snapshot rollback completed for Point In Time on VD {1} PIT creation time {2} 356 = Controller ID: {0} Snapshot rollback progress on Point In Time on VD {1} PIT creation time {2} Progress = {3} 357 = Controller ID: {0} Snapshot repository 80% full on VD {1} SnapShot Repository VD: {2} 358 = Controller ID: {0} Snapshot repository full on VD {1} SnapShot Repository VD: {2} 359 = Controller ID: {0} Snapshot View 80% full on VD {1} SnapShot Repository VD: {2} 360 = Controller ID: {0} Snapshot view full on VD {1} SnapShot Repository VD: {2} 361 = Controller ID: {0} Repository lost for VD {1} 362 = Controller ID: {0} Repository restored for VD {1} 363 = Controller ID: {0} Snapshot encountered an unexpected internal error: {1} 364 = Controller ID: {0} Auto Snapshot enabled on VD {1} SnapShot Repository VD: {2} 365 = Controller ID: {0} Auto Snapshot disabled on VD {1} SnapShot Repository VD: {2} 366 = Controller ID: {0} Configuration command could not be committed to disk, please retry! 367 = Controller ID: {0} COD on PD updated as it was stale. PD: {1} 368 = Controller ID: {0} Power state change failed on PD = {1} Previous = {2} Current = {3} 369 = Controller ID: {0} VD is not available. VD: {1} 370 = Controller ID: {0} VD is available. VD: {1} 371 = Controller ID: {0} VD is used for CacheCade. VD: {1} Capacity - Logical Blocks: {2} 372 = Controller ID: {0} VD is being cached in CacheCade. VD: {1} SSC VD {2} 373 = Controller ID: {0} VD is no longer being cached in CacheCade. VD: {1} SSC VD {2} 374 = Controller ID: {0} Snapshot deleted due to resource constraints on VD {1} SnapShot Repository VD: {2} 375 = Controller ID: {0} Auto Snapshot failed for VD {1} SnapShot Repository VD: {2} 376 = Controller ID: {0} Controller reset on-board expander 377 = Controller ID: {0} CacheCade VD capacity changed. VD: {1} Capacity - Logical Blocks: {2} 378 = Controller ID: {0} Battery cannot initiate transparent learn cycles 379 = Controller ID: {0} Activation Key was applied Action {1} MegaRAID Advanced Software(s): {2} 380 = Controller ID: {0} Snapshot schedule properties changed on VDs: {1} 381 = Controller ID: {0} Snapshot scheduled action is due - Schedule timer expired on VDs: {1} 382 = Controller ID: {0} Performance Metrics: collection command: {1} 383 = Controller ID: {0} MegaRAID Advanced Software Options have been transferred Action {1} MegaRAID Advanced Software(s): {2} 384 = Controller ID: {0} Advanced Software Options Serial number: {1} 385 = Controller ID: {0} Advanced Software Options Serial number mismatched. Key vault Serial number is: 386 = Controller ID: {0} Battery cannot support data retention for more than few hours. Hour: {1} Please replace the battery 387 = Controller ID: {0} Power Policy changed on VD : {1} Previous = {2} Now = {3} 388 = Controller ID: {0} Cannot transition to max power savings on VD : {1} 389 = Controller ID: {0} Host driver is loaded and operational 390 = Controller ID: {0} Mirror broken on VD : {1} 391 = Controller ID: {0} Mirror joined on VD : {1} 392 = Controller ID: {0} Link failed on Wide Port {1} Link {2} 393 = Controller ID: {0} Link restored on Wide Port {1} Link {2} 394 = Controller ID: {0} Memory module FRU is {1} 395 = Controller ID: {0} Cache-vault power pack is sub-optimal. Please replace the pack. 396 = Controller ID: {0} Foreign configuration auto-import did not import any drives 397 = Controller ID: {0} Cache-vault microcode update required. 398 = Controller ID: {0} {1} CacheCade(TM) capacity exceeds maximum allowed size, extra capacity is not used 399 = Controller ID: {0} Protection information lost on VD : {1} 400 = Controller ID: {0} Diagnostics passed for PD : {1} 401 = Controller ID: {0} Diagnostics failed for PD : {1} 402 = Controller ID: {0} Server Power capability Diagnostic Test Started 403 = Controller ID: {0} Drive Cache settings enabled during rebuild for PD : {1} 404 = Controller ID: {0} Drive Cache settings restored after rebuild for PD : {1} 405 = Controller ID: {0} {1} PD commissioned as Emergency spare 406 = Controller ID: {0} Reminder: Potential non-optimal configuration due to PD commissioned as emergency spare {1} 407 = Controller ID: {0} Consistency Check suspended on VD : {1} 408 = Controller ID: {0} Consistency Check resumed on VD : {1} 409 = Controller ID: {0} Background Initialization suspended on VD : {1} 410 = Controller ID: {0} Background Initialization resumed on VD : {1} 411 = Controller ID: {0} Reconstruction suspended on VD : {1} 412 = Controller ID: {0} Rebuild suspended on PD : {1} 413 = Controller ID: {0} Replace drive operation suspended on PD : {1} 414 = Controller ID: {0} Reminder: Consistency Check suspended on VD : {1} 415 = Controller ID: {0} Reminder: Background Initialization suspended on VD : {1} 416 = Controller ID: {0} Reminder: Reconstruction suspended on VD : {1} 417 = Controller ID: {0} Reminder: Rebuild suspended on PD : {1} 418 = Controller ID: {0} Reminder: Replace drive operation suspended on PD : {1} 419 = Controller ID: {0} Reminder: Patrol Read suspended 420 = Controller ID: {0} Erase aborted on PD : {1} 421 = Controller ID: {0} Erase failed on PD : {1} (Error {2}) 422 = Controller ID: {0} Erase progress on PD : {1} Progress = {2} 423 = Controller ID: {0} Erase started on PD : {1} 424 = Controller ID: {0} Erase completed on PD : {1} 425 = Controller ID: {0} Erase aborted on VD : {1} 426 = Controller ID: {0} Erase failed on VD : {1} 427 = Controller ID: {0} Erase progress on VD : {1} Progress = {2} 428 = Controller ID: {0} Erase started on VD : {1} 429 = Controller ID: {0} Erase complete on VD : {1} 430 = Controller ID: {0} Potential leakage during erase on VD : {1} 431 = Controller ID: {0} Battery charging was suspended due to high battery temperature 432 = Controller ID: {0} NVCache firmware update was successful 433 = Controller ID: {0} NVCache firmware update failed 434 = Controller ID: {0} VD : {1} access blocked as cached data in CacheCade(TM) is unavailable 435 = Controller ID: {0} CacheCade(TM) disassociate started on VD : {1} 436 = Controller ID: {0} CacheCade(TM) disassociate completed on VD : {1} 437 = Controller ID: {0} CacheCade(TM) disassociate failed on VD : {1} 438 = Controller ID: {0} CacheCade(TM) disassociate progress on VD : {1} Progress = {2} 439 = Controller ID: {0} CacheCade(TM) disassociate aborted by user on VD : {1} 440 = Controller ID: {0} Link speed changed on SAS port {1} PHY = {2} 441 = Controller ID: {0} Advanced Software Options was deactivated for Premium Feature(s): - {1} 442 = Controller ID: {0} VD : {1} is now accessible 443 = Controller ID: {0} VD : {1} is using CacheCade(TM) 444 = Controller ID: {0} VD : {1} is no longer using CacheCade(TM) 445 = Controller ID: {0} Patrol Read aborted on PD : {1} 446 = Controller ID: {0} Transient error detected while communicating with PD : {1} 447 = Controller ID: {0} PI error in cache for LD : {1} at LBA : {2} 448 = Controller ID: {0} Flash downloaded image is not supported 449 = Controller ID: {0} BBU mode selected - {1} 450 = Controller ID: {0} Periodic Battery Relearn was missed and Rescheduled to : {1} 451 = Controller ID: {0} Controller reset requested by host. 452 = Controller ID: {0} Controller reset requested by host, completed. 453 = Controller ID: {0} L3 cache error has been detected. 454 = Controller ID: {0} L2 cache error has been detected. 455 = Controller ID: {0} Controller booted in headless mode with errors. 456 = Controller ID: {0} Controller booted to safe mode due to critical errors. 457 = Controller ID: {0} Warning Error during boot : {1}% 458 = Controller ID: {0} Critical Error during boot : {1}% 459 = Controller ID: {0} Fatal Error during boot : {1}% #HAMR Events 460 = Controller ID: {0} Peer Controller entered HA Domain. 461 = Controller ID: {0} Peer Controller exited HA Domain. 462 = Controller ID: {0} Peer Controller now manages PD: {1} 463 = Controller ID: {0} Local Controller now manages PD: {1} 464 = Controller ID: {0} Peer Controller now manages VD: {1} 465 = Controller ID: {0} Local Controller now manages VD: {1} 466 = Controller ID: {0} Target ID conflict detected on VD:{1} access is restricted from Peer controller 467 = Controller ID: {0} Shared access policy set for VD: {1} 468 = Controller ID: {0} Exclusive access policy set for VD: {1} 469 = Controller ID: {0} VD is incompatible in the HA Domain. VD: {1} 470 = Controller ID: {0} Peer controller is incompatible. 471 = Controller ID: {0} Controllers in the HA domain are incompatible. 472 = Controller ID: {0} Controller property mismatch detected with Peer controller. 473 = Controller ID: {0} FW version does not match Peer controller. 474 = Controller ID: {0} Advanced Software Option mismatch detected with Peer controller. 475 = Controller ID: {0} Cache mirroring is Online. 476 = Controller ID: {0} Cache mirroring is Offline. 477 = Controller ID: {0} Cached data from Peer controller is unavailable for VD: {1} access policy is set to Blocked. 478 = Controller ID: {0} Cache-vault power pack is not supported. Please replace the pack. 479 = Controller ID: {0} Temperature is above warning threshold on PD: {1} Temperature: {2} Celsius 480 = Controller ID: {0} Temperature is above critical threshold on PD: {1} Temperature: {2} Celsius 481 = Controller ID: {0} Temperature is normal on PD: {1} Temperature: {2} Celsius 482 = Controller ID: {0} IOs are being throttled on PD: {1} 483 = Controller ID: {0} IOs are normal on PD: {1} 484 = Controller ID: {0} Life left on PD: {1} (Life Left: {2}% and Life Left Thresholds - Warning: {3}%, Critical: {4}%) 485 = Controller ID: {0} Life is below Optimal on PD: {1} (Life Left: {2}% and Life Left Thresholds - Warning: {3}%, Critical:{4}%) 486 = Controller ID: {0} Life is Critical on PD: {1} (Life Left: {2}% and Life Left Thresholds - Warning: {3}%, Critical:{4}%) 487 = Controller ID: {0} PD failure, device locked-up. PD: {1} 488 = Controller ID: {0} Host driver needs to be upgraded {1} 489 = Controller ID: {0} Direct communication with peer controller(s) was not established. Please check proper cable connections 490 = Controller ID: {0} Firmware image does not contain signed component 491 = Controller ID: {0} Authentication failure of the signed firmware image 492 = Controller ID: {0} Setting VD as boot device. VD: {1} 493 = Controller ID: {0} Setting PD as boot device. PD: {1} 494 = Controller ID: {0} The BBU temperature is changed to {1} Celsius 495 = Controller ID: {0} The Controller temperature is changed to {1} Celsius 496 = Controller ID: {0} NVCache capacity is too less to support data backup. Write-back VDs will be converted to write-through 497 = Controller ID: {0} NVCache data backup capacity has decreased, consider replacement 498 = Controller ID: {0} NVCache device failed, cannot support data retention 499 = Controller ID: {0} Boot Device reset, setting target ID as invalid 500 = Controller ID: {0} Write back Nytro cache size mismatch between the servers. The Nytro cache size was adjusted to %ld GB 501 = Controller ID: {0} VD %ld is not shared between servers but assigned for caching. Write back Nytro cache content of the VD will be mirrored 502 = Controller ID: {0} Power watts usage base IOs throttle started {1} 503 = Controller ID: {0} Power base IOs throttle stopped 504 = Controller ID: {0} Controller tunable parameter(s) changed 505 = Controller ID: {0} Controller operating temperature within normal range, full operation restored 506 = Controller ID: {0} Controller temperature threshold exceeded. This may indicate inadequate system cooling. Switching to low performance mode 507 = Controller ID: {0} Controller supports HA mode, currently functioning with HA feature set 508 = Controller ID: {0} Controller supports HA mode, currently functioning with single controller feature set 509 = Controller ID: {0} Cache-vault components mismatch. Write-back VDs will be converted write-through 510 = Controller ID: {0} Controller has entered into maintenance mode {1} 511 = Controller ID: {0} Controller has returned to normal mode 512 = Controller ID: {0} Topology is in mode {1} 513 = Controller ID: {0} Cannot enter expected mode because LD would not be supported. Mode: {1} LD: {2} Reason: {3} 514 = Controller ID: {0} Cannot enter expected mode because PD would not be supported. Mode: {1} PD: {2} Reason: {3} 515 = Controller ID: {0} Cache Flush started 516 = Controller ID: {0} Cache Flush finished 517 = Controller ID: {0} Cache Flush aborted by user 518 = Controller ID: {0} Controller personality changed to {2} mode 519 = Controller ID: {0} Configuration automatically created by {1} 522 = Controller ID: {0} Initialization aborted on {1} due to controller reset 523 = Controller ID: {0} Peer controller security key mismatch 524 = Controller ID: {0} Peer controller security key match 525 = Controller ID: {0} Compatible in the HA domain 530 = Controller ID: {0} MegaRAID Solution will shut down due to maximum temperature threshold exception. This may indicate inadequate system cooling. 531 = Controller ID: {0} Shutdown chassis command received from host. 532 = Controller ID: {0} Restart chassis command received from host. 533 = Controller ID: {0} Controller Information changed. 534 = Controller ID: {0} Hidden policy not set for all LDs in the array. 535 = Controller ID: {0} PD {1} is not enterprise class self encrypting drive. Encryption capability of the drive will be disabled 536 = Controller ID: {0} Controller firmware was updated with force option 537 = Controller ID: {0} Default access policy is set to read/write mode. 538 = Controller ID: {0} Disabling writes to flash due to a critical error. Reboot the system to enable writes to flash again. 539 = Controller ID: {0} Disabling writes to flash as the part has gone bad. 540 = Controller ID: {0} Locate LED started on PD {1} 541 = Controller ID: {0} Locate LED stopped on PD {1} 542 = Controller ID: {0} Patrol read aborted due to conflict with other background operations on PD {1} 543 = Controller ID: {0} Bad Media Events on PD: {1} {2} Number of Errors: {3} 544 = Controller ID: {0} PD has bad Performance: {1} {2} {3} #Added for SCGCQ00819877 545 = Controller ID: {0} SuperCap Health After Learn Cycles Capacitance: {1} Resistance: {2} Voltage: {3} Temperature: {4} Over55DegBucketCount: {5} Over60DegBucketCount: {6} Over65DegBuccketCount: {7} Over70DegBucketCount: {8} Over75DegBucketCount: {9} 546 = Controller ID: {0} Controller personality will change PCI ID to (PCI ID {1}/{2}/{3}/{4}) 550 = Controller ID: {0} System reset required. # CCoH related events 49152 = Cache Group: Added Cache Device {0} 49153 = Cache Group: Removed Cache Device {0} 49154 = Cache Group: Added VD {0} 49155 = Cache Group: Removed VD {0} 49156 = Cache Group: VD went Offline. VD: {0} 49157 = Cache Group: VD is Ready for Online. VD: {0} 49158 = Cache Group: VD is Online. VD: {0} # Warhawk related events 65522 = Controller ID: {0} SSD is in unlocked state. Device Id: {1} Encl Index: {2} Slot Number {3} 65523 = Controller ID: {0} SSD is in locked state. Device Id: {1} Encl Index: {2} Slot Number {3} 65525 = Controller ID: {0} Temperature has exceeded critical temperature threshold Flags: {1} SensorOrSlot: {2} Temperature: {3} Threshold: {4} Device Id: {5} 65526 = Controller ID: {0} Temperature has exceeded warning temperature threshold Flags: {1} SensorOrSlot: {2} Temperature: {3} Threshold: {4} Device Id: {5} 65527 = Controller ID: {0} Power throttling is now removed Percent Power Throttled: {1} PCI Slot Available Power: {2} 65528 = Controller ID: {0} Percent Power Throttled: {1} PCI Slot Available Power: {2} 65529 = Controller ID: {0} Temperature has exceeded Critical level on Sensor: {1} Threshold: {2} Temperature: {3} 65530 = Controller ID: {0} Temperature has exceeded Warning level on Sensor: {1} Threshold: {2} Temperature: {3} 65531 = Controller ID: {0} The Backup Rail Monitor has failed 65532 = Controller ID: {0} SSD Life is exhausted on Slot: {1} Device Id: {2} Device Life: {3} Warning Level: {4} Error Level: {5} 65533 = Controller ID: {0} SSD Life is at warning level on Slot: {1} Device Id: {2} Device Life: {3} Warning Level: {4} Error Level: {5} 65534 = Controller ID: {0} SSD throttling is now removed on Slot: {1} Device Id: {2} Throttle: {3} 65535 = Controller ID: {0} SSD is being throttled on Slot: {1} Device Id: {2} Throttle: {3}
修改文件时间
将文件时间修改为当前时间的前一年
删除文件