文件操作 - Voltages.html
返回文件管理
返回主菜单
删除本文件
文件: /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/webapps/omsa/help/oem/hip/en/Voltages.html
编辑文件内容
<!-- #include VIRTUAL="/includes/global_format.inc.asp" --> <html> <head> <link rel="stylesheet" type="text/css" href="PG-ID.css"> <meta http-equiv="Content-Type" content="text/html; charset=ISO-8859-1"> <meta name="MS.LOCALE" content="EN"> <title>Voltage Probes Information</title> </head> <body bgcolor="#FFFFFF"> <!-- #include VIRTUAL="/includes/global_header.inc.asp" --> <!-- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ --> <h3><b><a name="top">Voltage Probes Information</a></b></h3> <p>Use this window to view status information reported by voltage probes that are located in your system.</p> <h4>User Privileges</h4> <table border="2" cellpadding="4" cellspacing="3" width="581"> <tr> <td width="174" align="left" valign="top" rowspan="2"><b>Selection</b></td> <td width="374" colspan="2" align="center" height="13" valign="top"><b>User Privileges</b></td> </tr> <tr> <td width="374" colspan="2" align="center" height="13" valign="top"><i> U=User; P=Power User; A=Administrator; NA=Not Applicable</i></td> </tr> <tr> <td width="174" height="21" align="left" valign="top"> </td> <td width="175" height="21" align="center" valign="top"><b>View</b></td> <td width="186" height="21" align="center" valign="top"><b>Manage</b></td> </tr> <tr> <td width="174" height="19" align="left" valign="top"> <em style="font-style: normal">Voltage Probes Information</em></td> <td width="175" align="center" height="19" valign="top">U, P, A</td> <td width="186" align="center" height="19" valign="top">P, A</td> </tr> </table><br> <table id="table1" border="0"> <tr> <td vAlign="top" align="left" width="21"> <img height="17" src="note.gif" width="17" border="0"></td> <td><span class="notes">NOTE: </span>For more details on user privilege levels, see "<a href="../../oma/en/UserLevels.html">Privilege Levels in the Server Administrator GUI</a>."</td> </tr> </table> <h4><b>Voltage</b> </h4> <p>A system's components are rated for a specific operating voltage. Voltage probes are placed on different components within the system to ensure adequate voltage and to prevent damage that can result from excessive voltage.</p> <p>The <b>Voltage</b> <b>Probes</b> window displays information about the following: <ul> <li>Status of each voltage probe in the system</li> <li>Actual voltage read by the probe at the time of the request; a snapshot of voltage at a particular point in time (<b>Reading</b>)</li> <li>Minimum and maximum warning threshold values for voltage probes</li> </ul> <p>[<a href="#top">Back to Top</a>]</p> <h4><b>Status</b></h4> <p>Voltage probes report <font color="#000000">voltages</font> at different locations within a chassis to the Server Administrator Instrumentation Service. Voltage status is one of the following states:</p> <table border="0" width="18%"> <tr> <td width="17%"><img border="0" src="ok.gif" width="16" height="16"></td> <td width="56%"></td> <td width="56%"><b>Normal/OK</b></td> </tr> <tr> <td width="17%"><img border="0" src="non-crit.gif" width="16" height="16"></td> <td width="56%"></td> <td width="56%"><b>Warning/Noncritical</b></td> </tr> <tr> <td width="17%"><img border="0" src="critical.gif" width="16" height="16"></td> <td width="56%"></td> <td width="56%"><b>Critical/Nonrecoverable</b></td> </tr> <tr> <td width="17%">(Blank)</td> <td width="56%"></td> <td width="56%"><b>Unknown</b></td> </tr> </table> <h4><b>Voltage Probe Fields</b></h4> <p>Some voltage probe fields differ according to the type of firmware that your system has: BMC or ESM. </p> <table border="0" width="80%"> <tr> <td width="21" valign="top" align="left"><img border="0" src="note.gif" width="17" height="17"></td> <td width="681"><span class="notes"><b>NOTE</b>:</span> The fields listed on this page cover possible configurations. </td> </tr> </table> <table border="0" width="80%"> <tr> <td width="21" valign="top" align="left"><img border="0" src="note.gif" width="17" height="17"></td> <td width="681"><span class="notes"><b>NOTE</b>:</span> For some probes, the value for <b>Reading</b> is <em>Good</em> or <em>Bad</em> rather than an editable, numeric value. </td> </tr> </table> <table border="0" width="80%"> <tr> <td width="21" valign="top" align="left"><img border="0" src="note.gif" width="17" height="17"></td> <td width="681"><span class="notes"><b>NOTE</b>:</span> Some threshold values are not editable on BMC-based systems.</td> </tr> </table> <p> </p> <table border="0" cellpadding="4" cellspacing="3" width="80%"> <tr> <td width="30%" valign="top" align="left"><strong>Status</strong></td> <td width="70%" valign="top" align="left"><font color="#000000">Indicates whether the event type for the probe is <i>Normal/OK</i>, <i>Warning/Noncritical</i>, or <i>Failure/Nonrecoverable</i>.</font></td> </tr> <tr> <td width="30%" valign="top" align="left"><strong>Probe Name</strong></td> <td width="70%" valign="top" align="left"><font color="#000000">Displays the alphanumeric text that uniquely identifies a voltage probe. For example, Motherboard. </font></td> </tr> <tr> <td width="30%" valign="top" align="left"><strong>Reading</strong></td> <td width="70%" valign="top" align="left"><font color="#000000">Displays a snapshot of voltages measured by the probe at a given time.</font></td> </tr> <tr> <td width="30%" valign="top" align="left"><strong>Minimum Warning Threshold</strong></td> <td width="70%" valign="top" align="left"><font color="#000000">Displays the lowest acceptable voltage that is recommended for system operation. Values that fall below this voltage level result in warning events.</font></td> </tr> <tr> <td width="30%" valign="top" align="left"><strong>Maximum Warning Threshold</strong></td> <td width="70%" valign="top" align="left"><font color="#000000">Displays the highest acceptable voltage that is recommended for system operation. Values that exceed this voltage result in warning events.</font></td> </tr> <tr> <td width="30%" valign="top" align="left"><strong>Minimum Failure Threshold</strong></td> <td width="70%" valign="top" align="left"><font color="#000000">Displays the lowest acceptable voltage that is required for system operation. Values that fall below this voltage result in critical/failure events.</font></td> </tr> <tr> <td width="30%" valign="top" align="left"><strong>Maximum Failure Threshold</strong></td> <td width="70%" valign="top" align="left"><font color="#000000">Displays the highest acceptable voltage that is required for system operation. Values that exceed this voltage result in critical/failure events.</font></td> </tr> </table> <h4>Managing Voltage Probes</h4> <p>For information on how to set warning thresholds for voltage probes, see "<a href="EditVoltageProbes.html">Edit Voltage Probes</a>."</p> <p>For information on how to set alert actions for voltage probes, see "<a href="ListLRA.html">Set Alert Actions</a>."</p> <p>[<a href="#top">Back to Top</a>]</p> <h4>Other Window Controls</h4> <table cellSpacing="3" cellPadding="4" width="80%" border="0"> <tbody> <tr> <td vAlign="top" align="left" width="30%"><b>Print</b></td> <td vAlign="top" align="left" width="70%"><font color="#000000">Prints a copy of the open window to your default printer.</font></td> </tr> </tbody> </table> <table cellSpacing="3" cellPadding="4" width="80%" border="0"> <tbody> <tr> <td vAlign="top" width="30%"><b>Export</b></td> <td vAlign="top" width="70%">Saves a text file containing the contents of this window (the values of each data field separated by a customizable delimiter) to a destination you specify.</td> </tr> </tbody> </table> <table cellSpacing="3" cellPadding="4" width="80%" border="0"> <tbody> <tr> <td vAlign="top" align="left" width="30%"><b>Email</b></td> <td vAlign="top" align="left" width="70%">E-mails the contents of this window to your designated recipient. See the <em>Server Administrator User's Guide</em> for instructions about configuring your Simple Mail Transfer Protocol (SMTP) server.</td> </tr> <tr> <td vAlign="top" align="left" width="30%"><b>Refresh</b></td> <td vAlign="top" align="left" width="70%">Updates the screen with latest information.</td> </tr> </tbody> </table> <p>[<a href="#top">Back to Top</a>]</p> <!-- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ --> <!-- #include VIRTUAL="/includes/global_footer.inc.asp" --> </body> </html>
修改文件时间
将文件时间修改为当前时间的前一年
删除文件